Pace Corporation logoPace CorporationHVAC Consultants and Contractors
++++
LOC: IND-INSEC: 01AREF: VRV-SYS
X: 104.92Y: 882.10SCALE: NTS

Architects corner

HVAC support in Indore that fits the design and construction workflow

Pace Corporation helps architects, interior designers, and builders move from concept to site execution with clearer cooling recommendations, BOQs, and coordination inputs.

++
Phase 01

Site Inputs

Collect drawings, room usage, occupancy, elevation, exposure, and service route constraints.

[SYS-01]
++
Phase 02

Load Calculation

Prepare practical cooling-load guidance and recommend equipment capacities for each area.

[SYS-02]
++
Phase 03

BOQ & Budget

Create brand-wise BOQ and budget estimates for tendering, client approval, and purchase planning.

[SYS-03]
++
Phase 04

Execution Support

Coordinate drawings, installation sequencing, commissioning, and post-installation service handover.

[SYS-04]
DRAWING // MODEL-3D-EXPLODEDVIEWPORT: ISOMETRIC // COMP: VRV
Z-AXIS EXPLODE: ON_HOVER
01 / CONCRETE SLAB
02 / HVAC DUCTS & VRV ROUTING
03 / CEILING DIFFUSERS & CASSETTES
Hover card stack to explode drawing
++++
LOC: IND-INSEC: 01AREF: VRV-SYS
X: 104.92Y: 882.10SCALE: NTS

Deliverables

Useful inputs before tendering and before execution

The section is written for professionals who need practical HVAC information without slowing down design reviews or client approvals.

Share project drawings
DWG // 01

Room-wise heat load guidance

+01
DWG // 02

Brand and system recommendation

+02
DWG // 03

BOQ and budget estimate support

+03
DWG // 04

Outdoor unit and route coordination

+04
DWG // 05

Site visit and drawing review

+05
DWG // 06

AMC planning after handover

+06
++++
LOC: IND-INSEC: 01AREF: VRV-SYS
X: 104.92Y: 882.10SCALE: NTS

Workspace utilities

Interactive calculation tools and CAD references

Calculate rough capacities for spacing guidelines and download typical CAD details for installation route coordination.

Quick HVAC Tonnage Estimator

Drafting-phase heating & cooling capacity estimations

CALCULATOR OUT // SCHEMATIC-ESTIMATE
Heat Load

23,438 BTU/h

Est. Tonnage

1.95 Tons

VRV Index Recommendation

2.4 HP

Architectural Fit Tip

Recommended: 1.5 - 2.0 Ton Multi-Split or 1.5 - 2.0 HP VRV Ceiling Cassette. Perfect for clean architectural layouts.

Drafting Resource Hub

Standard coordinate drawing files for AutoCAD and Revit imports

PDF (Product Catalog) // 10.1 MB

Daikin VRV Alpha Product Catalogue 2026

PDF (Product Catalog) // 3.0 MB

Daikin VRV S Product Catalogue

PDF (Product Catalog) // 2.2 MB

Daikin Room Air Conditioner (RA) Master Catalogue

PDF (Product Catalog) // 3.8 MB

Daikin Single Split Ducted (SA) Catalogue

PDF (Product Catalog) // 1.6 MB

Daikin Non-Inverter Packaged AC Catalogue

Need customized DWGs for your specific site slab grids? Email your structural files to **pacecorporation1@gmail.com** and our planning office will coordinate the duct routing sleeve drawings.

++++
LOC: IND-INSEC: 01AREF: VRV-SYS
X: 104.92Y: 882.10SCALE: NTS

Structural & Tender Tools

Coordinate clearances and generate boilerplate BOQs

Calculate structural clearances to prevent on-site concrete beam clashing, and instantly output pre-approved technical specifications for tender drafting.

Beam Clash & Duct Clearance Analyzer

Verify false ceiling heights under structural concrete beams

3100 mm
2800mm3300mm3800mm
600 mm
300mm600mm900mm
200 mm
100mm (Slim Cassette)250mm (Medium Static)400mm (High Static)
2400 mm
2200mm2500mm2800mm
GRID SCHEMATIC // ELEVATION V-1SCALE: 1 UNIT = 1MMFL // 0.00SLAB LEVELCONCRETE BEAMHVAC DUCTFALSE CEILING: 2250mmTARGET MIN: 2400mm600H1: 3100H2: 2250

Clearance Warning

Ceiling clearance (2250mm) drops below your desired target of 2400mm. Consider dropping the ceiling locally (soffit box) or shifting duct runs.

Coming Soon

The Technical Specification & BOQ Generator is being upgraded. Check back soon.

++++
LOC: IND-INSEC: 01AREF: VRV-SYS
X: 104.92Y: 882.10SCALE: NTS

Daikin VRV Indoor Unit Fit-Guide

Ceiling heights, clearances, and draft tolerances for architects

CAT // DUCTABLE
Premium & Seamless

Ceiling Mounted Ductable (Concealed)

Completely hidden inside the false ceiling with only the linear diffusers visible. Requires coordinates for sheet-metal duct routes early.

Ceiling Clearance250mm - 300mm false ceiling drop
Noise Index22 - 35 dB (Ultra quiet)
Best ApplicationLiving rooms, high-end offices, hotel rooms
CAT // CASSETTE_4WAY
Symmetrical Sizing

4-Way Blow Ceiling Cassette

Distributes air in 4 directions. Fits flush into standard grid ceiling frameworks without needing duct networks.

Ceiling Clearance290mm false ceiling depth
Noise Index28 - 38 dB
Best ApplicationShowrooms, open-plan offices, clinics
CAT // WALL_MOUNTED
Simple & Cost-Effective

Wall Mounted Split / VRV Unit

Standard unit installed on structural walls. Easy access for service with no false ceiling changes needed.

Ceiling Clearance100mm top clearance / 150mm side clearance
Noise Index19 - 33 dB
Best ApplicationSmall offices, guest rooms, retrofit sites
CAT // CASSETTE_1WAY
Ultra Slim Profile

1-Way Blow Slim Cassette

Single-directional cooling designed specifically for shallow ceilings and long narrow corridors where space is restricted.

Ceiling Clearance150mm ultra-slim ceiling drop
Noise Index24 - 34 dB
Best ApplicationNarrow corridors, entry foyers, master bedrooms

Ready for site inputs?

Share drawings, room details, or a site visit requirement.

Pace Corporation can help with load calculation, BOQ, brand recommendation, installation planning, and AMC support.